TRACE: Two-Stage Detector-Response Estimation With Angular Cosine Expansion for Ring Artifact Correction in Photon-Counting CT
Detector response nonuniformity introduces systematic projection errors and ring artifacts in photon-counting detector computed tomography (PCD-CT). In measured PCD-CT data, residual stripe amplitudes vary slowly with projection angle, which fixed-bias models cannot adequately capture. We propose TRACE, a two-stage unsupervised sinogram decomposition method for estimating and correcting these response-related errors. TRACE represents stripes as a fixed bias plus low-order discrete cosine transform (DCT) components, using a small number of coefficients to describe angular variations at each detector element. A learnable analysis--synthesis architecture represents the ideal projections, whi...