Certified AI Triage of ICU Alarms
In the VTaC benchmark 71% of ventricular-tachycardia alarms are false, but silencing a real one can delay recognition of a dangerous arrhythmia. We reframe alarm reduction as three-way triage (retain, suppress, or defer) and bound the decision this analysis treats as harmful: among suppressed alarms, the fraction that were genuine stays below a user-set budget with 95% confidence, under i.i.d. event sampling. Alarms sharing a waveform record are dependent, so the clustered analysis is a sensitivity check. On the official split a 5% budget certifies in all three seeds, suppressing 74.8% of false alarms while silencing 1.5% of genuine ones, at AUROC 0.953 and Challenge Score 83.33, numerica...
| Authors | Mohammed Sameer Syed, Rozhin Yasaei |
|---|---|
| Primary category | cs.LG |
| Published | 11 September 2026 |
| Last updated at source | 11 September 2026 |
Silytics shows public metadata from arXiv and links to the original. Information may be incomplete or out of date. Last refreshed 17 October 2026. Licenses and terms of the original apply to the work itself. Not financial, legal or professional advice.