Sign inGet started
Paper · arXiv

LightMedSeg-ISLES: Stroke Lesion Segmentation with 81x Fewer Parameters than nnU-Net

Large networks and ensembles often lead medical image segmentation challenges, but their storage and inference demands complicate deployment. We present LightMedSeg-ISLES, a 1.26-million-parameter pipeline for T1-weighted stroke lesion segmentation in ISLES'26. On a 146-case held-out cohort, flip test-time augmentation produces 0.618 mean Dice and 0.599 lesion-wise F1. A 102.35-million-parameter nnU-Net ResEnc-L produces 0.634 Dice and 0.544 lesion-wise F1 after size filtering. LightMedSeg therefore retains 97.5\% of nnU-Net's Dice with 81.4$\times$ fewer parameters while improving lesion-wise F1 by 0.055. Its four-pass TTA operating point requires 4.7$\times$ fewer FLOPs per standardized...

AuthorsGiorgi Nikvashvili, Hanxue Gu, Jie Bao et al.
Primary categorycs.CV
Published9 September 2026
Last updated at source14 October 2026
cs.CVcs.LG
Embed this entry
<iframe src="https://silytics.si/embed/item/d0da212c-e574-40c7-879a-e6b0f2be0f9d" width="420" height="190" style="border:0" loading="lazy" title="Silytics entry"></iframe>

Free, no tracking. More about feeds and embeds.

Silytics shows public metadata from arXiv and links to the original. Information may be incomplete or out of date. Last refreshed 17 October 2026. Licenses and terms of the original apply to the work itself. Not financial, legal or professional advice.