Auditing Recorded Predictive Lead Service-Line Classifications Against Physical Verification: A Statewide Study of New York

Under the US Lead and Copper Rule Revisions, a utility may determine a service line's material with a predictive model instead of inspecting it. New York State publishes, per address, which method was used. Almost no address carries both a model classification and a physical verification, so the check is between populations within a utility rather than paired addresses. We screen all 153 New York localities that classified at least 100 addresses this way. Seventy-five (49%), covering 125,990 addresses or 57% of those screened, record one value. Zero variance alone is not misconduct: 68 of the 75 match their own verification or have too little to test. Seven are contradicted by their own c...